<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-05 08-35-58
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 60 dBuV VOLTAGE
Pilot RDS Phase Difference
7.2 kHz 3.6 kHz 21 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 73 kHz 10060 15,7356
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
6,5 dBr 7,96 dBr 8,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 8:35, 5.02.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (60 dBuV) Max at: 73 kHz MIN: 11 kHz % above 75 kHz: 15,7356 Acquired: 2025/02/05 8:34:54 Total samples: 10060 Equivalent time: 0:08:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,8 dBr MIN: 6,5 dBr AVE: 7,96 dBr % above 10,0 dBr: 0,0 Last value: 8,0 dBr (2025/02/05 8:34:54) Station: 96.90 MHz, signal: 4/5 (60 dBuV) 08:28 08:29 08:30 08:31 08:32 08:33 08:34 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality